Interzinc B. Storage Conditions: All painting materials shall be stored in a clean, dry, well ventilated place, protected from sparks, flame. A three component, metallic, zinc rich epoxy primer which passes Slip B coefficient. Interzinc B complies with SSPC Paint 20 and contains minimum 80%. Interzinc Call for Price. A two component high solids, low VOC metallic zinc- rich epoxy primer formulated on proprietary polymer technology which provides.

Author: Dokinos Zulkizuru
Country: Grenada
Language: English (Spanish)
Genre: Sex
Published (Last): 20 April 2013
Pages: 32
PDF File Size: 15.44 Mb
ePub File Size: 13.17 Mb
ISBN: 136-7-32367-386-8
Downloads: 8914
Price: Free* [*Free Regsitration Required]
Uploader: Faeshicage

Temperature and Humidity Requirements: Once agreed interzzinc in writing it serves as a guide for itnerzinc finished work. Verify that substrate and workspace temperature and humidity conditions are interzjnc accordance with requirements of this section. Pipes, ducts, conduits, hangers and supports, equipment, and equipment enclosures exposed to view in all rooms and spaces.

Commencement of application is acceptance of substrate. Severe Atmosphere Application – Industrial areas with high humidity and aggressive environments.

Pipes, ducts, conduits, hangers and supports, equipment, and equipment enclosures exposed to weather or view – corrosion-resistant finish. Maintain environmental conditions temperature, humidity, and ventilation within limits recommended by manufacturer for optimum results. Equipment and application procedures must conform to the coating manufacturer’s application instructions.

Store and dispose of hazardous materials, and materials inherzinc by hazardous materials, in accordance with intetzinc of local authorities having jurisdiction.

Provide masking, drop cloths or other suitable coverings to prevent overspray onto surfaces not intended to be affected by Work in this section. Where necessary, cleaning or other corrections of the surfaces to receive coatings are the responsibility of the installer of the incompatible substrate.

Store materials in strict accordance with manufacturers documented instructions. Protect adjacent areas from over spray of coating material. Submit plan, section, elevation and perspective drawings as necessary to depict system configuration, design considerations and application procedures. For each finish product specified, two complete sets of color chips representing manufacturer’s full range of available materials.

  ARKUSZE MATURALNE PAZDRO PDF

All products listed in this section must be manufactured under the appropriate follow-up service with each container bearing the certified label mark. Pipes, ducts, conduits, hangers and supports, equipment, and equipment enclosures exposed to view in all rooms and spaces except mechanical rooms, electrical rooms, and utility rooms.

Retain only coating systems specified and delete all others.

The following is one example of how a mock-up on a large project might be specified. Temporary protection and heat shall be maintained at this minimum temperature for 24 hours before, during and 24 hours after material application. Protect work area from windblown dust and rain. Submit applicators current certification as a manufacturer trained and approved applicator.

Interzinc – A k i r a

Interior environment with high humidity and exposure to air pollution. Sequence and coordinate application of coatings with Work in other sections which would interfere with efficient protective coating application. If this location falls within a mile radius of the project site, then Interchar can contribute to earning Materials and Resources Credit 5.

International Paint has operations in 54 countries worldwide imterzinc over 3, employees. All surfaces to receive coatings must be clean, dry and free of oil, grease, loose mill scale, dirt, dust or other foreign substances which would impair bond of the material to the substrate.

A copy of the transport document and manufacturers conformance certificate shall be attached to the material delivery QC form. Grind smooth all weld spatter and defects prior to commencement of coating application.

Low Atmosphere or Interior Applications – Rural area, low pollution, dry environments.

SECTION HIGH PERFORMANCE SPECIALTY COATINGS

When deciding on the extent of the mock-up, consider all intezrinc major different types of work on the project. Before proceeding with the work, the applicator will apply the primer and finish coat to a representative substrate section of square feet in size.

Do not apply coatings under environmental conditions outside manufacturer’s absolute limits. To be selected by Architect from manufacturer’s full range of available colors. Primer applied off site must be in accordance with the provisions of Section Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.

  IFMIS KENYA PDF

Marine, offshore and coastal areas with high salinity. Submit manufacturer documentation that the fireproofing product complies with the specified contract requirements. International Paint, LLC, which is located at: Coordinate with Section and Contract Drawings for all Moderate Atmosphere areas of the project.

No coating material may be procured or delivered to the project site prior to the review and acceptance of the proposed materials by the Architect in writing. The Manufacturer’s quality management system must be assessed and registered by an independent registrar as conforming to the requirements of ISO The relative humidity of the application area shall not exceed a maximum of 85 percent for 24 hours prior, during and 24 hours after the application of the material.

At project closeout, provide to Owner or Owners Representative an executed copy of the manufacturer’s standard limited warranty against manufacturing defect, outlining its terms, conditions, and exclusions from coverage.

High Performance coatings applied in the field with Company specializing in manufacturing products listed in this section with a minimum of ten 10 years documented experience.

Interzinc 315

Do not commence application of coatings until the contractor, applicator and inspector have examined the surfaces to receive Work in this section, and determined that the surfaces are acceptable to receive the specified materials.

Apply finish coat in accordance with the manufacturer’s application instructions. International Protective Coatings is the leading supplier of high performance Protective Coatings and forms part of Akzo Nobel, a market driven, technology based company specializing in Coatings, Chemicals and Pharmaceuticals. Information must demonstrate itnerzinc of product and performance to the specified material and complete systems.